Four Advantages Of Electromagnetic Pulse Valve Do You Know?

About the introduction of electromagnetic pulse valve we have mentioned in the previous article, but for the advantages of electromagnetic pulse valve we did not say in great detail, may be many customers and friends for the advantages of electromagnetic pulse valve is not very understanding. Therefore, the small series of Eurotech environmental protection will give you a detailed introduction today. What are the advantages of the electromagnetic pulse valve?

One: The leakage is blocked, the inner leakage is easy to control, and the use of safety

Electromagnetic pulse valves are particularly safe to use, especially for corrosive, toxic or cryogenic media.

Two: The system is simple, then the computer, low prices

The solenoid valve itself has a simple structure and a low price, and is easier to install and maintain than other types of actuators such as regulating valves. What is even more remarkable is that the self-contained system is much simpler and the price is much lower. Because the solenoid valve is a switch signal control, it is very convenient to connect with the industrial control computer. In today's era of widespread computer availability and sharply lower prices, the advantages of solenoid valves are even more pronounced.

Three: action express, small power, light and compact

Solenoid valve response time can be as short as several milliseconds, and even pilot solenoid valves can be controlled within tens of milliseconds. Because of self-looping, it reacts more sensitively than other self-controlled valves. Well-designed solenoid valve coil power consumption is very low, is an energy-saving product; can also be achieved simply trigger action, automatically maintain the valve position, usually no power at a time. The electromagnetic valve has a small size, which saves space and is light and beautiful.

Four: Models are diverse and widely used

The advantage of the electromagnetic pulse valve is very prominent, so it is very versatile. The progress of solenoid valve technology is also centered around how to overcome congenital deficiencies and how to better develop the inherent advantages.

Dust removal frame size measurement method

As long as you grasp these points carefully, you can avoid making mistakes in the measurement of the dust skeleton. Even if there are, it will not be too big:

First, measure the diameter of the dust board, the size of the outer diameter is smaller than the size of the inner diameter of the flower board and the dust bag.

Second, the spacing between the dust-removing frame ring beam is 200 is basically stereotyped.


Third, the total length of dust removal frame is less than 5 cm dust bag, or as short as possible, do not be too long, otherwise the dust bag will be forced by the dust skeleton.

Fourth, the Venturi tube dust removal framework using a reasonable streamline and thickness of the material processing, venturi streamline shape determines the size of the intensity of the jet flow and cleaning thoroughly.

Fifth. The diameter of the outer diameter of the dust-removal frame is the best in terms of the manufacturer's standard size. This can save a lot of unnecessary mold making and consumption. Learn more electromagnetic valve about from Senotay.

Comments

Popular posts from this blog

The Electromagnetic Valve 2019

Electromagnetic pulse valves (also known as diaphragm valves) are compressed air "switches" for pulse bag filter dust cleaning systems. By the control of the output signal of the pulse jet control instrument, the filter bag is cleaned by one row (chamber), so that the resistance of the filter is kept within the set range, so as to ensure the processing capacity and dust collection efficiency of the filter. DMF-Z electromagnetic pulse valve  is a right-angle valve, and the angle between the inlet and outlet is 90 degrees, which is suitable for the installation connection between the airbag and the dust blower tube. The air flow is unobstructed and it can provide the required clear air pulse. DMF-ZM electromagnetic pulse valve is the same as the "Z" series of the right-angle valve, suitable for airbag and dust collector spray pipe installation connection, the import and export of the two ends with a fixed nut for installation so that installation and us

Electrostatic Dust Precipitator

  1. Introduction of electrostatic dust precipitators   The power supply of the electrostatic precipitator consists of a control box, a step-up transformer and a rectifier. The output voltage of the power supply also has a great influence on the dust removal efficiency. Therefore, the operating voltage of the electrostatic precipitator must be maintained at 40-75kV or even above 100kV.   2. Basic structure of electrostatic dust precipitators   The electrostatic dust precipitators  are composed of two parts: one part is the main system of the electrostatic precipitator; the other part is the power supply device that provides high-voltage direct current and the low-voltage automatic control system. The high-voltage power supply system supplies power to the step-up transformer, and the dust collector of the dust collector is grounded. The low voltage electric control system is used to control the temperature of the electromagnetic vibrating hammer, the ash discharging electrode, the ash c

Ash Discharge Valve

The opening and closing part of the ash discharge valve  electric plug valve is a gate plate, and the direction of movement of the gate plate is perpendicular to the direction of the fluid. The electric plug valve can only be fully opened and fully closed and cannot be adjusted or throttled. The gate has two sealing surfaces. The two sealing surfaces of the most commonly used mode gate valves form a wedge, and the wedge angle varies with the valve parameters. Principle: There is a round opening of a diameter on the gate, and the opening and closing of the gate makes the round opening on the gate to completely separate from and match with the diameter. Electric three-way valves are used for air conditioning, thermal ventilation, heat treatment in heat treatment plants, and industrial fluid control. Air-conditioning, heating, ventilation, domestic hot water and other civil systems and chemical, petroleum and metallurgical and fluid automation. Our dust collection syste