 1. Selection principle of cyclone type dust collector

 

① The amount of gas purged by the cyclone type dust collector should be consistent with the amount of dust-containing gas that needs to be treated. The diameter of the cyclone type dust collector should be as small as possible. If the required air volume is large, it is advisable to use several small diameter cyclones in parallel.  

 

② The inlet wind speed of the cyclone dust collector should be maintained at 18~23m/s. When it is too low, the dust removal efficiency will decrease: when it is too high, the resistance loss and power consumption will increase, and the dust removal efficiency will not increase significantly.  

 

③ The selected cyclone type dust collector has small resistance loss, low power consumption, simple structure and easy maintenance.  

 

④ The smallest dust particles that can be captured by the cyclone type dust collector should be slightly smaller than the dust particle size in the gas to be processed.  

 

⑤ When the temperature of the dust-containing gas is high, keep warm to avoid condensation of moisture in the dust collector. If the dust does not absorb moisture and the dew point is 30-50℃, the temperature of the dust collector should be at least about 30℃ higher. If the dust has strong water absorption (such as cement, gypsum and alkali-containing dust ), the dew point is 20-50℃ The temperature of the dust collector should be 40-50℃ higher than the dew point temperature.  

 

⑥ The structure of the cyclone dust collector should be airtight to ensure no air leakage. Especially for negative pressure operation, more attention should be paid to the reliability of the discharge air lock device.  

 

⑦ Flammable and explosive dust (such as coal powder) should be equipped with explosion-proof device. The usual practice for explosion-proof devices is to add a safety explosion-proof valve to the inlet pipe.  

 

⑧ When the dust viscosity is small, the maximum allowable dust concentration is related to the diameter of the cyclone, that is, the larger the diameter, the greater the allowable dust concentration.

 

Hebei Ou Tai Environmental Protection Equipment Co., Ltd. is a professional dust collection system manufacturer. We provide ash valve, tops elevator buckets, ventilation butterfly valve, Baghouse Filter, Electrostatic Dust Collector, industrial dust collection systems and so on. Want to know more? Please contact us.



 

Comments

Popular posts from this blog

The Electromagnetic Valve 2019

Electromagnetic pulse valves (also known as diaphragm valves) are compressed air "switches" for pulse bag filter dust cleaning systems. By the control of the output signal of the pulse jet control instrument, the filter bag is cleaned by one row (chamber), so that the resistance of the filter is kept within the set range, so as to ensure the processing capacity and dust collection efficiency of the filter. DMF-Z electromagnetic pulse valve  is a right-angle valve, and the angle between the inlet and outlet is 90 degrees, which is suitable for the installation connection between the airbag and the dust blower tube. The air flow is unobstructed and it can provide the required clear air pulse. DMF-ZM electromagnetic pulse valve is the same as the "Z" series of the right-angle valve, suitable for airbag and dust collector spray pipe installation connection, the import and export of the two ends with a fixed nut for installation so that installation and us

Electrostatic Dust Precipitator

  1. Introduction of electrostatic dust precipitators   The power supply of the electrostatic precipitator consists of a control box, a step-up transformer and a rectifier. The output voltage of the power supply also has a great influence on the dust removal efficiency. Therefore, the operating voltage of the electrostatic precipitator must be maintained at 40-75kV or even above 100kV.   2. Basic structure of electrostatic dust precipitators   The electrostatic dust precipitators  are composed of two parts: one part is the main system of the electrostatic precipitator; the other part is the power supply device that provides high-voltage direct current and the low-voltage automatic control system. The high-voltage power supply system supplies power to the step-up transformer, and the dust collector of the dust collector is grounded. The low voltage electric control system is used to control the temperature of the electromagnetic vibrating hammer, the ash discharging electrode, the ash c

Ash Discharge Valve

The opening and closing part of the ash discharge valve  electric plug valve is a gate plate, and the direction of movement of the gate plate is perpendicular to the direction of the fluid. The electric plug valve can only be fully opened and fully closed and cannot be adjusted or throttled. The gate has two sealing surfaces. The two sealing surfaces of the most commonly used mode gate valves form a wedge, and the wedge angle varies with the valve parameters. Principle: There is a round opening of a diameter on the gate, and the opening and closing of the gate makes the round opening on the gate to completely separate from and match with the diameter. Electric three-way valves are used for air conditioning, thermal ventilation, heat treatment in heat treatment plants, and industrial fluid control. Air-conditioning, heating, ventilation, domestic hot water and other civil systems and chemical, petroleum and metallurgical and fluid automation. Our dust collection syste