 Maintenance instructions for bag filter:

 

1. When the bag type dust collector is under maintenance, first cut off the power supply. The operator must carry the key of the operation panel and hang a sign "under maintenance, no operation" on the operation panel.

 

2. The transmission devices such as the rapping device, star unloader, exhaust fan, and couplings, transmission belts, transmission coupling wheels, etc., must be equipped with protective covers to prevent the bolts from loosening, causing the belts and chains broken to hurt people.

 

3. During the daily inspection or operation, the operator must strictly prevent the clothes from being twisted into the transmission device when handling the fault temporarily. When entering the ash collection hopper to clean the ash or entering the filter bag room to hang the bag, labor protection equipment must be worn to prevent dust from getting into the eyes or burning the skin.

 

4. For bag type dust collector that handle flammable and explosive dust gas, such as bag dust collectors used in coal mills, the dust in the dust collector should be removed frequently to prevent combustion or explosion, and kindling material should be prevented from entering. It is strictly forbidden to use electric welding or gas welding to repair the pipeline or shell during operation.

 

5. For the positive pressure glass fiber bag type dust collector that handles high temperature gas, measures to prevent heat stroke should be taken when entering the gas distribution room to hang fiberglass filter bag in summer.

 

6. When entering the dust collector for treatment of harmful and toxic gases, it is necessary to prevent possible hypoxia and harmful gas poisoning accidents. The gas in the system can be replaced with air.

 

7. After the overhaul is over, you must carefully check whether there are tools or other sundries falling into the equipment. Check whether the protective cover is properly installed, and do not finish it carelessly.

 

8. When the equipment of the dust collection system is turned on and off, you must contact operators of other positions to get permission, after which you can start or stop in the order of on and off specified in the operating regulations.

 

The main maintenance items of the dust hood are as follows:

 

a. Whether the position of the mobile dust hood is correct.

 

b. Deformed or damaged state.

 

c. Whether the connection part with the pipeline is intact.

 

d. Confirm the dust accumulation status and clean it.

 

e. If a water cooling device is installed, check the displacement. The temperature of the drain and the presence or absence of leakage should be kept cool.

 

As a dust collector manufacturer, Hebei Ou Tai Environmental Protection Equipment Co., Ltd. is located in Botou City, a famous "dust-removing hometown." The factory is located in Xihuan Industrial Park, Botou City, Hebei Province, which is located in the center of Beijing, Tianjin, Jinan, and Shijiazhuang. Beijing-Shanghai Expressway, Beijing-Shanghai Railway, 106 State Road, 104 National Road walk through the city, the traffic is very convenient.

 

 


Comments

Popular posts from this blog

The Electromagnetic Valve 2019

Electromagnetic pulse valves (also known as diaphragm valves) are compressed air "switches" for pulse bag filter dust cleaning systems. By the control of the output signal of the pulse jet control instrument, the filter bag is cleaned by one row (chamber), so that the resistance of the filter is kept within the set range, so as to ensure the processing capacity and dust collection efficiency of the filter. DMF-Z electromagnetic pulse valve  is a right-angle valve, and the angle between the inlet and outlet is 90 degrees, which is suitable for the installation connection between the airbag and the dust blower tube. The air flow is unobstructed and it can provide the required clear air pulse. DMF-ZM electromagnetic pulse valve is the same as the "Z" series of the right-angle valve, suitable for airbag and dust collector spray pipe installation connection, the import and export of the two ends with a fixed nut for installation so that installation and us...

Ash Discharge Valve

The opening and closing part of the ash discharge valve  electric plug valve is a gate plate, and the direction of movement of the gate plate is perpendicular to the direction of the fluid. The electric plug valve can only be fully opened and fully closed and cannot be adjusted or throttled. The gate has two sealing surfaces. The two sealing surfaces of the most commonly used mode gate valves form a wedge, and the wedge angle varies with the valve parameters. Principle: There is a round opening of a diameter on the gate, and the opening and closing of the gate makes the round opening on the gate to completely separate from and match with the diameter. Electric three-way valves are used for air conditioning, thermal ventilation, heat treatment in heat treatment plants, and industrial fluid control. Air-conditioning, heating, ventilation, domestic hot water and other civil systems and chemical, petroleum and metallurgical and fluid automation. Our dust collection s...

Standard Single Layer Felt Filter Bags

  Ⅰ . Introduction of standard single-layer felt filter bag   Industrial polypropylene (PP) and polyester (PE) standard felt filter bags, single-sided slip surface to prevent fiber migration, gradient pore deep filter type, no internal support layer. Use nearly 30 kinds of fibers with different diameters, and use fiber mixing equipment to make filter bags.   Ⅱ . Features of standard single-layer felt filter bag   1. Stitching method: ultrasonic welding or thread suture.   2. Sealing ring: polypropylene and polyester SDS, STS, galvanized steel ring or stainless steel ring.   3. Sealing ring connection method: ultrasonic welding or thread stitching.   4. Accuracy range: 1, 3, 5, 10, 25, 50, 75, 100, 150, 200 microns.   5. Efficiency: relative accuracy, single filtration efficiency is 85%.   6. Surface treatment: Smooth surface treatment to prevent fiber and leachate from freeing.   7. Material grade: fully comply with FDA grade requirement...