Skip to main content

Electromagnetic Solenoid Pulse Valve

 Electromagnetic solenoid pulse valve is a dust collector diaphragm valve that is directly controlled by electrical signal. The dust collector solenoid valve in Senotay is to control the size of the oil pressure in the oil circuit. Generally, the dust collector valve is installed in the main oil circuit or damper back pressure oil circuit in order to reduce the oil pressure shock when shifting and locking unlocking, so that the equipment operation maintain a smooth state.

Dust Collector Electromagnetic Solenoid Pulse Valve For Sale

Senotay is a professional manufacturer and supplier who is committed to providing high-quality electromagnetic dust collector solenoid valves at low prices. We offer DMF-Z electromagnetic pulse valve, DMF-ZM electromagnetic pulse valve, DMF-Y electromagnetic pulse valve and DMF-T electromagnetic pulse valve. Contact us now if you are interested!

 

DMF-Z Right Angle Electromagnetic Pulse Valve

 

DMF-ZM 90 Degree Right Angle Pulse Jet Electromagnetic Valve

 

DMF-Y Submerged Electromagnetic Pulse Valve

 

DMF-T Straight-Through Electromagnetic Pulse Valve

 

Electromagnetic Solenoid Pulse Valve Working Principle

The diaphragm divides the dust collector solenoid valve into two chambers: the front and the back. When the compressed air enters the back chamber through the throttle hole, the pressure of the back chamber presses the diaphragm against the output of the electromagnetic solenoid pulse valve, and the dust collector valve is in the "closed" state. When the electrical signal of pulse blowing controller disappears, the armature of electromagnetic solenoid pulse valve is reset, the venting hole of rear air chamber is closed, and the pressure of rear air chamber rises so that the diaphragm presses against the valve outlet, and the dust collector solenoid valve is in the "closed" state.

 

Electromagnetic Solenoid Pulse Valve Advantages

Made of high quality aluminum alloy precision casting, the electromagnetic solenoid pulse valve is durable.

Good moisture-proof and corrosion-proof ability.

Electromagnetic pulse control, fast opening and closing of the dust collector solenoid valve.

Easy to install and maintain for continuous use.

Good sealing performance, safe and reliable.

 

Dust Collector Solenoid Valve Installation

 

1. Pay attention to check whether the dust collector solenoid valve are damaged in the transportation process before use.

2. Clear the gas supply pipe of debris before installation. Pay attention to the correct direction of gas flow and receiver during installation of electromagnetic solenoid pulse valve.

3. All O-rings should be properly lubricated during installation.

4. There are three pins on the electromagnetic solenoid pulse valve coil with special plugs, one of them with " " symbol is the grounding pin, users can decide whether to ground according to their needs. (In general, the voltage is less than 36V can not be grounded, more than 36V should be grounded.) The other two are coil power pins, respectively, with the pulse blowing control instrument corresponding to the order of the terminals and the dust collector valve with the terminals of the common line connected. Pay attention to whether the voltage meets the requirements.

5. Dust collector sub-air box (including the receiver) is determined by the user, the capacity of the sub-air box should be satisfied to provide a stable gas source for the electromagnetic pulse valve to work, the inner wall of the sub-air box should be clean and free of rust and other debris, the sub-air box has no leakage and meets the requirements of the relevant safety.

6. The electromagnetic solenoid pulse valve and the gas package and the blowing connection tube seals for the applicable temperature of -10 ℃ ~ 70 ℃. If you need high temperature seals, please specify when ordering.

 

Senotay is a trusted supplier of pulse jet right angle valve, contact us to get more info

 

As a dust collector manufacturer, we will do our best to meet all the needs of customers.

 



Comments

Popular posts from this blog

The Electromagnetic Valve 2019

Electromagnetic pulse valves (also known as diaphragm valves) are compressed air "switches" for pulse bag filter dust cleaning systems. By the control of the output signal of the pulse jet control instrument, the filter bag is cleaned by one row (chamber), so that the resistance of the filter is kept within the set range, so as to ensure the processing capacity and dust collection efficiency of the filter. DMF-Z electromagnetic pulse valve  is a right-angle valve, and the angle between the inlet and outlet is 90 degrees, which is suitable for the installation connection between the airbag and the dust blower tube. The air flow is unobstructed and it can provide the required clear air pulse. DMF-ZM electromagnetic pulse valve is the same as the "Z" series of the right-angle valve, suitable for airbag and dust collector spray pipe installation connection, the import and export of the two ends with a fixed nut for installation so that installation and us

Electrostatic Dust Precipitator

  1. Introduction of electrostatic dust precipitators   The power supply of the electrostatic precipitator consists of a control box, a step-up transformer and a rectifier. The output voltage of the power supply also has a great influence on the dust removal efficiency. Therefore, the operating voltage of the electrostatic precipitator must be maintained at 40-75kV or even above 100kV.   2. Basic structure of electrostatic dust precipitators   The electrostatic dust precipitators  are composed of two parts: one part is the main system of the electrostatic precipitator; the other part is the power supply device that provides high-voltage direct current and the low-voltage automatic control system. The high-voltage power supply system supplies power to the step-up transformer, and the dust collector of the dust collector is grounded. The low voltage electric control system is used to control the temperature of the electromagnetic vibrating hammer, the ash discharging electrode, the ash c

Ash Discharge Valve

The opening and closing part of the ash discharge valve  electric plug valve is a gate plate, and the direction of movement of the gate plate is perpendicular to the direction of the fluid. The electric plug valve can only be fully opened and fully closed and cannot be adjusted or throttled. The gate has two sealing surfaces. The two sealing surfaces of the most commonly used mode gate valves form a wedge, and the wedge angle varies with the valve parameters. Principle: There is a round opening of a diameter on the gate, and the opening and closing of the gate makes the round opening on the gate to completely separate from and match with the diameter. Electric three-way valves are used for air conditioning, thermal ventilation, heat treatment in heat treatment plants, and industrial fluid control. Air-conditioning, heating, ventilation, domestic hot water and other civil systems and chemical, petroleum and metallurgical and fluid automation. Our dust collection syste