Skip to main content

DMF-Z Right Angle Electromagnetic Pulse Valve

DMF-Z Right Angle Electromagnetic Pulse Valve Product introduction:
The valve is imported from abroad (also known as the diaphragm valve) is the compressed air "switch" of the pulse bag filter dust cleaning system is controlled by the output signal of the pulse injection controller, and the filter bag is cleaned by the row (chamber). Ash, so that the dust collector's resistance is maintained within the set range, in order to ensure that the dust collector processing capacity and vacuum efficiency.

DMF-Z Right Angle Electromagnetic Pulse Valve Features:
The DMF-Z electromagnetic pulse valve is a right-angle valve. The angle between the inlet and outlet is 90°. It is suitable for the mounting connection between the helium cylinder and the dust blower tube. The gas flow is unobstructed, and it can provide the turbulent gas flow that meets the requirements.

DMF-Z Right Angle Electromagnetic Pulse Valve working principle:
The diaphragm divides the electromagnetic pulse valve into two air chambers, front and rear. When the compressed air is turned on, the compressed air enters the rear air chamber through the throttle hole. At this time, the pressure of the air chamber presses the diaphragm against the output of the valve. The pulse valve is in the "closed" state.

The electric signal of the pulse injection controller causes the electromagnetic pulse valve armature to move, the air chamber vent hole opens after the valve, the rear chamber quickly loses pressure, the diaphragm moves back, the compressed air is blown through the valve outlet, and the electromagnetic pulse valve is "opened" status.

f:id:senotay:20190915174413j:plain
Pulse injection control instrument electrical signal disappeared, electromagnetic pulse valve armature reset, after the air chamber vent hole closed, the rear chamber pressure increased so that the diaphragm close to the valve output, the electromagnetic pulse valve is in the "closed" state.

Our dust collector manufacturer has always been on the basis of equality and mutual benefit with domestic and foreign customers to establish long-term friendly trade relations, warmly welcome Chinese and foreign customers to call or letter us for business negotiations!

Comments

Popular posts from this blog

The Electromagnetic Valve 2019

Electromagnetic pulse valves (also known as diaphragm valves) are compressed air "switches" for pulse bag filter dust cleaning systems. By the control of the output signal of the pulse jet control instrument, the filter bag is cleaned by one row (chamber), so that the resistance of the filter is kept within the set range, so as to ensure the processing capacity and dust collection efficiency of the filter. DMF-Z electromagnetic pulse valve  is a right-angle valve, and the angle between the inlet and outlet is 90 degrees, which is suitable for the installation connection between the airbag and the dust blower tube. The air flow is unobstructed and it can provide the required clear air pulse. DMF-ZM electromagnetic pulse valve is the same as the "Z" series of the right-angle valve, suitable for airbag and dust collector spray pipe installation connection, the import and export of the two ends with a fixed nut for installation so that installation and us

Electrostatic Dust Precipitator

  1. Introduction of electrostatic dust precipitators   The power supply of the electrostatic precipitator consists of a control box, a step-up transformer and a rectifier. The output voltage of the power supply also has a great influence on the dust removal efficiency. Therefore, the operating voltage of the electrostatic precipitator must be maintained at 40-75kV or even above 100kV.   2. Basic structure of electrostatic dust precipitators   The electrostatic dust precipitators  are composed of two parts: one part is the main system of the electrostatic precipitator; the other part is the power supply device that provides high-voltage direct current and the low-voltage automatic control system. The high-voltage power supply system supplies power to the step-up transformer, and the dust collector of the dust collector is grounded. The low voltage electric control system is used to control the temperature of the electromagnetic vibrating hammer, the ash discharging electrode, the ash c

Ash Discharge Valve

The opening and closing part of the ash discharge valve  electric plug valve is a gate plate, and the direction of movement of the gate plate is perpendicular to the direction of the fluid. The electric plug valve can only be fully opened and fully closed and cannot be adjusted or throttled. The gate has two sealing surfaces. The two sealing surfaces of the most commonly used mode gate valves form a wedge, and the wedge angle varies with the valve parameters. Principle: There is a round opening of a diameter on the gate, and the opening and closing of the gate makes the round opening on the gate to completely separate from and match with the diameter. Electric three-way valves are used for air conditioning, thermal ventilation, heat treatment in heat treatment plants, and industrial fluid control. Air-conditioning, heating, ventilation, domestic hot water and other civil systems and chemical, petroleum and metallurgical and fluid automation. Our dust collection syste