Skip to main content

ZC Type Mechanical Rotary Blow Flat Bag Filter

ZC Type Mechanical Rotary Blow Flat Bag Filter Introduction:
The industrial dust collection systems adopt a circular body structure with uniform force, good anti-knocking performance, compact structure, high-pressure blower and blower cleaning, and is not limited by the air source condition, and uses the resistance to automatically control the blowback dust to save energy and prolong the use of the bag; Regional indoor installations can be installed outdoors in other areas, and can be widely used in many sectors such as machinery, foundry, mining, smelting, building materials, and food chemical.

Users should pay attention to the high temperature, high concentration, fine particles of dust should choose A type, and vice versa B type is appropriate, such as the concentration of more than 15g/m3 should be preceded by a cyclone dust collector(For coarse nuclear dust can be relaxed as appropriate).
f:id:senotay:20190915174308j:plain
ZC Type Mechanical Rotary Blow Flat Bag Filter Model indication:
144ZC-II-500-ANP570 rotary counter blowing flat bag filter.
Item 1: 144 is the number of filter bags (only)
Item 2: ZC refers to the beginning of the pinyin of the rewinding blow, in which "Z" refers to the beginning of the Chinese pinyin of "turning" and "C" refers to the beginning of the Chinese pinyin of "blowing".
Item 3: II- refers to the design number.
Item 4: 500 refers to the length of the bag (meters).
Item 5: According to the different filter speed V, the dust collector is divided into A type and B type size. A type size is used for an air volume of V=1.0~1.5/min. Type B size is used for V = 2.0~2.5/minute air volume.
Item 6: According to the rotating wind direction of the population, it can be divided into N-rotation and S-rotation. N indicates that the inlet rotates counterclockwise, S indicates that the inlet rotates clockwise, and the serialized drawings are rotated counterclockwise (that is, N-rotation).
Item 7: According to the form of the outlet duct, there are two kinds of exits: the flat exit and the lower exit. P means the flat exit, X means the lower exit, and the serialized drawings are drawn as flat exits (that is, P-type).


Item 8: 570 is the nominal filter area (m3).

Comments

Popular posts from this blog

The Electromagnetic Valve 2019

Electromagnetic pulse valves (also known as diaphragm valves) are compressed air "switches" for pulse bag filter dust cleaning systems. By the control of the output signal of the pulse jet control instrument, the filter bag is cleaned by one row (chamber), so that the resistance of the filter is kept within the set range, so as to ensure the processing capacity and dust collection efficiency of the filter. DMF-Z electromagnetic pulse valve  is a right-angle valve, and the angle between the inlet and outlet is 90 degrees, which is suitable for the installation connection between the airbag and the dust blower tube. The air flow is unobstructed and it can provide the required clear air pulse. DMF-ZM electromagnetic pulse valve is the same as the "Z" series of the right-angle valve, suitable for airbag and dust collector spray pipe installation connection, the import and export of the two ends with a fixed nut for installation so that installation and us

Electrostatic Dust Precipitator

  1. Introduction of electrostatic dust precipitators   The power supply of the electrostatic precipitator consists of a control box, a step-up transformer and a rectifier. The output voltage of the power supply also has a great influence on the dust removal efficiency. Therefore, the operating voltage of the electrostatic precipitator must be maintained at 40-75kV or even above 100kV.   2. Basic structure of electrostatic dust precipitators   The electrostatic dust precipitators  are composed of two parts: one part is the main system of the electrostatic precipitator; the other part is the power supply device that provides high-voltage direct current and the low-voltage automatic control system. The high-voltage power supply system supplies power to the step-up transformer, and the dust collector of the dust collector is grounded. The low voltage electric control system is used to control the temperature of the electromagnetic vibrating hammer, the ash discharging electrode, the ash c

Ash Discharge Valve

The opening and closing part of the ash discharge valve  electric plug valve is a gate plate, and the direction of movement of the gate plate is perpendicular to the direction of the fluid. The electric plug valve can only be fully opened and fully closed and cannot be adjusted or throttled. The gate has two sealing surfaces. The two sealing surfaces of the most commonly used mode gate valves form a wedge, and the wedge angle varies with the valve parameters. Principle: There is a round opening of a diameter on the gate, and the opening and closing of the gate makes the round opening on the gate to completely separate from and match with the diameter. Electric three-way valves are used for air conditioning, thermal ventilation, heat treatment in heat treatment plants, and industrial fluid control. Air-conditioning, heating, ventilation, domestic hot water and other civil systems and chemical, petroleum and metallurgical and fluid automation. Our dust collection syste