DMF-Z Right Angle Electromagnetic Pulse Valve

DMF-Z Right Angle Electromagnetic Pulse Valve Product introduction:

The electromagnetic pulse valve is imported from abroad (also known as the diaphragm valve) is the compressed air "switch" of the pulse bag filter dust cleaning system is controlled by the output signal of the pulse injection controller, and the filter bag is cleaned by the row (chamber). Ash, so that the dust collector's resistance is maintained within the set range, in order to ensure that the dust collector processing capacity and vacuum efficiency.

 

DMF-Z Right Angle Electromagnetic Pulse Valve Features:

The DMF-Z electromagnetic pulse valve is a right-angle valve. The angle between the inlet and outlet is 90°. It is suitable for the mounting connection between the helium cylinder and the dust blower tube. The gas flow is unobstructed, and it can provide the turbulent gas flow that meets the requirements.

 

DMF-Z Right Angle Electromagnetic Pulse Valve working principle:

The diaphragm divides the electromagnetic pulse valve into two air chambers, front and rear. When the compressed air is turned on, the compressed air enters the rear air chamber through the throttle hole. At this time, the pressure of the air chamber presses the diaphragm against the output of the valve. The pulse valve is in the "closed" state.

 

The electric signal of the pulse injection controller causes the electromagnetic pulse valve armature to move, the air chamber vent hole opens after the valve, the rear chamber quickly loses pressure, the diaphragm moves back, the compressed air is blown through the valve outlet, and the electromagnetic pulse valve is "opened" status.

 

Pulse injection control instrument electrical signal disappeared, electromagnetic pulse valve armature reset, after the air chamber vent hole closed, the rear chamber pressure increased so that the diaphragm close to the valve output, the electromagnetic pulse valve is in the "closed" state.

 

If you are looking for diaphragm valve manufacturers, Senotay can be a competitable one among those diaphragm valve suppliers. Contact us to get more information about our products!


Comments

Popular posts from this blog

Electrostatic Dust Collector

The working principle of the electrostatic dust collector  is to use the high voltage electric field to ionize the flue gas. The dust charge in the air flow is separated from the air flow under the action of the electric field. The negative electrode is made of metal wires with different cross-sectional shapes and is called a discharge electrode. The positive electrode is made of metal plates of different geometries and is called a collecting electrode. The performance of an electrostatic precipitator is affected by three factors, the nature of the dust, the configuration of the equipment, and the flow rate of the flue gas. The specific resistance of dust is an index for evaluating conductivity, and it has a direct effect on the dust removal efficiency. The specific resistance is too low, dust particles are difficult to maintain on the dust collecting electrode, causing it to return to the air flow. The specific resistance is too high, and the dust particles that reach the dus...

The Electromagnetic Valve 2019

Electromagnetic pulse valves (also known as diaphragm valves) are compressed air "switches" for pulse bag filter dust cleaning systems. By the control of the output signal of the pulse jet control instrument, the filter bag is cleaned by one row (chamber), so that the resistance of the filter is kept within the set range, so as to ensure the processing capacity and dust collection efficiency of the filter. DMF-Z electromagnetic pulse valve  is a right-angle valve, and the angle between the inlet and outlet is 90 degrees, which is suitable for the installation connection between the airbag and the dust blower tube. The air flow is unobstructed and it can provide the required clear air pulse. DMF-ZM electromagnetic pulse valve is the same as the "Z" series of the right-angle valve, suitable for airbag and dust collector spray pipe installation connection, the import and export of the two ends with a fixed nut for installation so that installation and us...

Selection Principle of Cyclone Type Dust Collector

  1. Selection principle of cyclone type dust collector   ① The amount of gas purged by the cyclone type dust collector should be consistent with the amount of dust-containing gas that needs to be treated. The diameter of the cyclone type dust collector should be as small as possible. If the required air volume is large, it is advisable to use several small diameter cyclones in parallel.      ② The inlet wind speed of the cyclone dust collector should be maintained at 18~23m/s. When it is too low, the dust removal efficiency will decrease: when it is too high, the resistance loss and power consumption will increase, and the dust removal efficiency will not increase significantly.      ③ The selected cyclone type dust collector  has small resistance loss, low power consumption, simple structure and easy maintenance.      ④ The smallest dust particles that can be captured by the cyclone type dust collector should be slightly smaller than the dust particle siz...