The Electromagnetic Valve

 Electromagnetic pulse valves (also known as diaphragm valves) are compressed air "switches" for pulse bag filter dust cleaning systems. By the control of the output signal of the pulse jet control instrument, the filter bag is cleaned by one row (chamber), so that the resistance of the filter is kept within the set range, so as to ensure the processing capacity and dust collection efficiency of the filter.

 

DMF-Z electromagnetic pulse valve is a right-angle valve, and the angle between the inlet and outlet is 90 degrees, which is suitable for the installation connection between the airbag and the dust blower tube. The air flow is unobstructed and it can provide the required clear air pulse.

 

DMF-ZM electromagnetic pulse valve is the same as the "Z" series of the right-angle valve, suitable for airbag and dust collector spray pipe installation connection, the import and export of the two ends with a fixed nut for installation so that installation and use more Convenience.

 

The DMF-Y electromagnetic pulse valve is a submerged valve (also called an embedded valve). It is directly mounted on the gas distribution box and has better flow characteristics. The pressure loss has decreased and it is suitable for workplaces with low air supply pressure.

 

The DMF-T electromagnetic pulse valve is a straight-through valve with an included angle of 180 degrees between the inlet ports (the inlet and outlet centerlines are the same lines). The inlet is connected to the air reservoir and the outlet is connected to the injection pipe. The air flow is unobstructed and it can provide the required clear air pulse.

 

Hebei Ou Tai Environmental Protection Equipment Co., Ltd. is a professional dust collector manufacturer, we provide Baghouse Filter, Electrostatic Dust Collector, dust collector valve, Dust Collector Bags, industrial dust collection systems and etc. Want to know more? Please contact us.



Comments

Popular posts from this blog

Electrostatic Dust Collector

The working principle of the electrostatic dust collector  is to use the high voltage electric field to ionize the flue gas. The dust charge in the air flow is separated from the air flow under the action of the electric field. The negative electrode is made of metal wires with different cross-sectional shapes and is called a discharge electrode. The positive electrode is made of metal plates of different geometries and is called a collecting electrode. The performance of an electrostatic precipitator is affected by three factors, the nature of the dust, the configuration of the equipment, and the flow rate of the flue gas. The specific resistance of dust is an index for evaluating conductivity, and it has a direct effect on the dust removal efficiency. The specific resistance is too low, dust particles are difficult to maintain on the dust collecting electrode, causing it to return to the air flow. The specific resistance is too high, and the dust particles that reach the dus...

The Electromagnetic Valve 2019

Electromagnetic pulse valves (also known as diaphragm valves) are compressed air "switches" for pulse bag filter dust cleaning systems. By the control of the output signal of the pulse jet control instrument, the filter bag is cleaned by one row (chamber), so that the resistance of the filter is kept within the set range, so as to ensure the processing capacity and dust collection efficiency of the filter. DMF-Z electromagnetic pulse valve  is a right-angle valve, and the angle between the inlet and outlet is 90 degrees, which is suitable for the installation connection between the airbag and the dust blower tube. The air flow is unobstructed and it can provide the required clear air pulse. DMF-ZM electromagnetic pulse valve is the same as the "Z" series of the right-angle valve, suitable for airbag and dust collector spray pipe installation connection, the import and export of the two ends with a fixed nut for installation so that installation and us...

Selection Principle of Cyclone Type Dust Collector

  1. Selection principle of cyclone type dust collector   ① The amount of gas purged by the cyclone type dust collector should be consistent with the amount of dust-containing gas that needs to be treated. The diameter of the cyclone type dust collector should be as small as possible. If the required air volume is large, it is advisable to use several small diameter cyclones in parallel.      ② The inlet wind speed of the cyclone dust collector should be maintained at 18~23m/s. When it is too low, the dust removal efficiency will decrease: when it is too high, the resistance loss and power consumption will increase, and the dust removal efficiency will not increase significantly.      ③ The selected cyclone type dust collector  has small resistance loss, low power consumption, simple structure and easy maintenance.      ④ The smallest dust particles that can be captured by the cyclone type dust collector should be slightly smaller than the dust particle siz...