Skip to main content

P84 Filter Bags

 Ⅰ. Introduction of P84 filter bags

 

P84 filter bag is a flame-retardant, temperature-resistant and stable fiber filter material. Under the condition of 240 ℃, the machine of P84 polyimide fiber filter material will not change, and the highest temperature can reach 260 ℃. P84 fiber filter material has no melting point temperature and is natural golden yellow. P84 polyimide fiber filter material is not a hygroscopic fiber filter material (under the condition of 65% relative humidity, about 3% water absorption).

 

In addition, because the P84 fiber has a special (leaf-shaped) cross-sectional structure, it has a large filtering surface area and excellent filtering performance, so P84 fiber is often implanted on the surface of the filter material (the side of the dust facing side to improve the filtering performance of the filter material. ).

 

Ⅱ. Several common factors for P84 filter bag damage:

 

1. Product quality

 

The processing of P84 filter bags is the most important. In recent years, some small manufacturers have used small sewing machines as processing equipment, and used inferior threads and fabrics as raw materials in the processing operations, using fake and real ones. Once such filter materials enter the dust removal market, they often open the thread after they are not used for a long time. Phenomenon such as cracks and bottom drop. Although the size of the cloth bag is slightly smaller, it can be used, but after the filter material absorbs dust particles with a larger specific gravity, the bag will fall off after a period of use.

 

2. Operating temperature

 

Accurately select the corresponding 84 filter bag suitable for the dust temperature. If the temperature is too high, if the selected P84 filter bag exceeds the normal use temperature, the filter material will be burned seriously, and the service life will be shortened. Therefore, when selecting a filter bag, it is necessary to estimate the inlet temperature of the dust collector, and select a dust filter bag with a suitable temperature.

 

3. Dust medium

 

The choice of P84 filter bag depends on the nature of the dust, so the smoke and dust components to be treated are particularly important. Select the appropriate filter material according to the nature of the dust, so that the filter bag can absorb dust normally, and it will not affect its service life.

 

4. Filter wind speed

 

Another factor that causes the P84 filter bag is that the filter wind speed of the bag filter is too high. In recent years, some units have blindly reduced equipment costs and increased profits. When designing the bag filter equipment, the filter wind speed should be mastered, and excessive wind speed should not be coveted, otherwise the service life of the filter bag will be shortened. This will not save costs, but also bring greater troubles, which is not desirable.

 

As a dust collector manufacturer our company has always been on the basis of equality and mutual benefit with domestic and foreign customers to establish long-term friendly trade relations, warmly welcome Chinese and foreign customers to call or letter us for business negotiations!

 


Comments

Popular posts from this blog

The Electromagnetic Valve 2019

Electromagnetic pulse valves (also known as diaphragm valves) are compressed air "switches" for pulse bag filter dust cleaning systems. By the control of the output signal of the pulse jet control instrument, the filter bag is cleaned by one row (chamber), so that the resistance of the filter is kept within the set range, so as to ensure the processing capacity and dust collection efficiency of the filter. DMF-Z electromagnetic pulse valve  is a right-angle valve, and the angle between the inlet and outlet is 90 degrees, which is suitable for the installation connection between the airbag and the dust blower tube. The air flow is unobstructed and it can provide the required clear air pulse. DMF-ZM electromagnetic pulse valve is the same as the "Z" series of the right-angle valve, suitable for airbag and dust collector spray pipe installation connection, the import and export of the two ends with a fixed nut for installation so that installation and us

Electrostatic Dust Precipitator

  1. Introduction of electrostatic dust precipitators   The power supply of the electrostatic precipitator consists of a control box, a step-up transformer and a rectifier. The output voltage of the power supply also has a great influence on the dust removal efficiency. Therefore, the operating voltage of the electrostatic precipitator must be maintained at 40-75kV or even above 100kV.   2. Basic structure of electrostatic dust precipitators   The electrostatic dust precipitators  are composed of two parts: one part is the main system of the electrostatic precipitator; the other part is the power supply device that provides high-voltage direct current and the low-voltage automatic control system. The high-voltage power supply system supplies power to the step-up transformer, and the dust collector of the dust collector is grounded. The low voltage electric control system is used to control the temperature of the electromagnetic vibrating hammer, the ash discharging electrode, the ash c

Ash Discharge Valve

The opening and closing part of the ash discharge valve  electric plug valve is a gate plate, and the direction of movement of the gate plate is perpendicular to the direction of the fluid. The electric plug valve can only be fully opened and fully closed and cannot be adjusted or throttled. The gate has two sealing surfaces. The two sealing surfaces of the most commonly used mode gate valves form a wedge, and the wedge angle varies with the valve parameters. Principle: There is a round opening of a diameter on the gate, and the opening and closing of the gate makes the round opening on the gate to completely separate from and match with the diameter. Electric three-way valves are used for air conditioning, thermal ventilation, heat treatment in heat treatment plants, and industrial fluid control. Air-conditioning, heating, ventilation, domestic hot water and other civil systems and chemical, petroleum and metallurgical and fluid automation. Our dust collection syste